UNIVERSITY CLINIC OF OTOLARYNGOLOGY, HEAD AND NECK SURGERY

Combined Electrical-Acoustic Stimulation Systems

When examining larger groups of patients with hearing loss, it becomes apparent that hearing loss typically begins at high frequencies. As a result, many patients with hearing loss still have residual hearing at low frequencies that they can utilize with a hearing aid. However, in many cases, this residual hearing is no longer sufficient for good speech understanding, leading many of these patients to opt for a cochlear implant.
In 1999, Professor Ilberg in Frankfurt had the groundbreaking idea of combining electrical stimulation of the auditory nerve via a cochlear implant with the use of residual low-frequency hearing—that is, stimulating the ear both acoustically and electrically at the same time.

Fig. 1 www_eas1   Fig. 2www_eas.pdf - Adobe Reader

Fig. 1 Indications for combined electrical-acoustic stimulation (Source: MED-EL Deutschland GmbH)
Fig. 2 Example of a preoperative audiogram


The applicability of this procedure, known as EAS (Electrical-Acoustic Stimulation), is contingent upon several technological and medical prerequisites:

  1. The intact structures at the tip of the cochlea, which are responsible for the perception of low-frequency sounds, must not be damaged by the implantation. This requires extremely flexible electrode carriers, which must also be shorter than standard electrodes.
  2. The electrode must be surgically inserted into the cochlea using a particularly gentle procedure to preserve residual hearing in the low-frequency range.
  3. The hearing aid and speech processor must be housed together in a single casing and powered by the same batteries.
  4. A specialized strategy for adjusting the hearing aid and cochlear implant must ensure an optimal division of the frequency ranges to be stimulated acoustically and electrically.

Fig. 3 Fig. 4Nucleus 7 speech processor (CP 1000) by Cochlear (Source: Cochlear Ltd.)

Fig. 3 Sonnet 2 speech processor from MED-EL (Source: MED-EL GmbH Germany)
Fig. 4 Nucleus 7 speech processor (CP 1000) from Cochlear (Source: Cochlear Ltd.)

Pre-operative diagnostics, surgical procedures, and post-operative rehabilitation follow the same protocol as for cochlear implantation.

Presentation: ‘Hearing with Electroacoustic Stimulation’ by A. Suhr
from the patient forum at the conference held on
October 1 and 2, 2010
Device-Based Rehabilitation of Hearing Impairments
— From Hearing Aids to Cochlear Implants
“The Magdeburg Concept as a Multidisciplinary Approach”
read

Last Modification: 23.06.2026 - Contact Person:

Sie können eine Nachricht versenden an: Webmaster
Warning: error_log(/global/WEB_DAT/documents/var/log/errors-2026-11): failed to open stream: No space left on device in /global/WEB_DAT/documents/lib/base/Ego_System.php on line 1992